Minute Book, home
Coroner’s reportPrevention of future deaths · 2017-0404

“S are as follows: (a) During the course of evidence | heard that an (admitted)…”

Dated 17 Nov 2017, from the coroner for Cambridgeshire and Peterborough. Sent to 4 organisations or people.

A coroner wrote this report after an inquest, to warn the organisations below about a risk of further deaths.

Read the full report on judiciary.uk

How this works

The 56-day response deadline

Report put online after its 56 days

Organisations that receive a report must reply to the coroner within 56 days, saying what they will do or why they will do nothing. We show whether a response is published on judiciary.uk; a reply may have been sent and not yet published.

judiciary.uk put this report online on 15 Feb 2018, after the 56 days for replies had ended (12 Jan 2018). These dates can’t tell us whether a reply was due before it went online. A reply may have been sent and not yet published.

  1. Report dated17 Nov 2017
  2. Deadline12 Jan 2018
  3. Published on judiciary.uk15 Feb 2018
  4. Today23 Oct 2026

Watch this report

We’ll email you when a response is published on judiciary.uk, or when the 56 days to reply end with none published there yet. Free, and you can stop with one click.

Next we ask your name, then send a link to confirm and create your free account. Already have an account? Sign in

Responses from each recipient

Responses from each recipient
Sent toResponse
NHS EnglandResponse publishedPublished on judiciary.uk in February 2018.
North West Anglia NHS Foundation TrustNamed in the report as “North West Anglia NHS Trust”Response publishedPublished on judiciary.uk in February 2018.
Royal College of AnaesthetistsResponse published, not yet matchedA response is published with this report. We haven’t yet matched it to the organisation it’s from, so it may be this one’s.
The Difficult Airway SocietyResponse published, not yet matchedA response is published with this report. We haven’t yet matched it to the organisation it’s from, so it may be this one’s.

Some responses were published as scans, so their text was read automatically. Check the wording against the original before you quote it.

The coroner’s concerns

This report was published as a scan, so its text was read automatically. Check the wording against the original before you quote it.

S are as follows: (a) During the course of evidence | heard that an (admitted) “misunderstanding of physiology” led the (b) lead consultant anaesthetist involved in the treatment of Mr Saint to conclude that whilst the patient was receiving appropriate chest compressions during resuscitation efforts, the capnography indicating an absence of a CO2 end tidal wave on the monitor could be explained by the fact that Mr Saint was in cardiac arrest. This was a mistake since exhaled CO2 can virtually always be observed during cardiac arrest with correctly applied compressions and lung ventilation. The clear expert evidence was that, discounting a technical problem with the monitoring equipment (not applicable here), the absence of a proper CO2 end tidal wave could only in the most exceptional circumstances be accounted for by anything other than oesophageal intubation and certainly not by cardiac arrest. Further, the expert evidence indicated that such a “misunderstanding of the physiology” is one that is known to be shared by other anaesthetists. This is of particular concern given that the issue was specifically addressed in the 4" National Audit Project (NAP4) of the Royal College of Anaesthetists and the Difficult Airway Society: ‘Major Complications in Airway Management in the UK’ Report and Findings as long ago as March 2011 (at page 101): “Unsurprisingly, the outcome of unrecognised oesophageal intubation is usually very poor indeed. Tracheal intubation in theatre is nowadays carried out in the presence of a trained assistant and a tested and functioning capnograph. The latter, in particular, means that unrecognised oesophageal intubation rarely occurs in the theatre environment. In contrast to the ICU and emergency department cases where capnography was not used, in the cases of oesophageal intubation during anaesthesia capnography was in use during the event. The event progressed due to failure to correctly interpret capnography in the face of situations of peri-arrest or cardiac arrest. Capnography can become difficult to interpret during low cardiac output states and in cardiac arrest. However a flat line is not usual and even in cardiac arrest, during CPR, carbon dioxide is produced leading to an attenuated but visible capnography trace (see Figure 1). A completely flat capnograph in any circumstances should immediately raise the possibility that the tracheal tube is not in the trachea, or is obstructed. Active measures should be undertaken to confirm or exclude these diagnoses. Clinical signs are unreliable in these circumstances and it is recognised that oesophageal intubation may present both after apparent normal auscultation of the lungs and as cardiovascular collapse.” (Emphasis added). The Report made the following recommendation: “Training of all clinical staff who may intubate patients should include interpretation of capnography. Teaching should include recognition of the abnormal (but not flat) capnography trace during low cardiac output states and during cardiopulmonary resuscitation.”(page 103). am concerned that the evidence in this case, including the expert evidence, established that notwithstanding the findings and recommendations of the 2011 NAP4 there is a continuing failure to ensure that capnography is sufficiently understood and utilised by all clinical staff who may intubate patients. The evidence heard, including the expert evidence, confirmed that an integral part of the process of intubating a patient requires that the anaesthetist, following the placement of the intubation tube into the patient, observes the capnography for a period of up to 15 to 20 seconds to ensure that a “proper CO2 end tidal wave” can be detected; failure to do so would be a “fundamental and basic error” and a “serious error”. | am concerned that this procedure was not followed by either the lead consultant anaesthetist in this case or the anaesthetists who attended to assist him. The expert evidence indicated a lack of widespread, regular, mandatory on-going training for anaesthetists in drills dealing with crisis situations potentially facing an anaesthetic team particularly in relation to the issues of “task fixation” and “confirmatory bias”, and that such training would be beneficial. 6 ACTION SHOULD BE TAKEN In my opinion action should be taken to prevent future deaths and | believe you (and/or your organisation) have the power to take such action. 7 YOUR RESPONSE You are under a duty to respond to this report within 56 days of the date of this report, namely by 12" January 2018. |, the coroner, may extend the period.

An extract. Read the full report, including the circumstances of the death, on the Courts and Tribunals Judiciary website.

Source
judiciary.uk, Prevention of Future Deaths reports, 2017-0404
Added to Minute Book
8 Oct 2026
Reuse
We show short extracts and link to the original. We don’t host the full report.

Something wrong, such as a date or who it was sent to? Report a mistake

Is this report about someone close to you? You can ask us to remove names from our pages.

Contains public sector information licensed under the Open Government Licence v3.0. Source: Courts and Tribunals Judiciary, judiciary.uk. Open Government Licence v3.0

Ask about this report

AI

Summaries and questions, with page references. Pro and above.

Sign in to use